1.
Article in English | LILACS, BBO | ID: biblio-1448795

ABSTRACT

ABSTRACT Objective: To evaluate an imaging protocol for use as a diagnostic and calibration tool for dentists before and after practical activity. Material and Methods: Thirty photos of children's teeth with or without changes in dental enamel were selected and evaluated by a group of experienced dentists previously calibrated to establish the diagnosis defined as the gold standard. After instructions, the images were shown to a group of postgraduate dentists for free identification of dental changes. Subsequently, a lecture on molar incisor hypomineralization (MIH) was carried out, and, at 14 days and all calibration was performed using the criteria previously. The retest was performed at 28 days. After experience in clinical activity in the following two weeks, the post-test was performed at 49 days. Data were analyzed using Cohen's kappa coefficient. Results: Theoretical learning on the subject showed low inter-examiner agreement when the diagnosis of defects was made from images obtained from intraoral photographs. After clinical practice, there was greater intra-examiner agreement. After theoretical training, dentists started to identify different types of enamel alteration, although with low agreement between them. Conclusion: Clinical experience in theoretical and imaging training favored the identification of defects. However, it is necessary to improve the protocol to establish a reliable and viable diagnostic method for calibration in MIH.


Subject(s)
Humans , Male , Female , Dental Enamel Hypoplasia/diagnostic imaging , Molar Hypomineralization/diagnostic imaging , Calibration/standards , Photography, Dental/instrumentation
2.
Aval. psicol ; 21(2): 127-139, abr.-jun. 2022. il, tab
Article in Portuguese | LILACS, INDEXPSI | ID: biblio-1447458

ABSTRACT

A Bateria de Provas de Raciocínio (BPR-5) é um instrumento bastante utilizado para avaliação da inteligência no Brasil, possuindo três formas: infantil (1º ao 6º ano do Ensino Fundamental), Forma A (7º ao 9º ano do Ensino Fundamental) e Forma B (Ensino Médio e Superior). Visando a possibilidade de comparar os resultados entre sujeitos que respondem a formas diferentes, o presente estudo objetivou: (a) calibrar os itens das três formas pelo modelo de Rasch, realizando a equalização por itens comuns de modo a obter uma escala equiparável para as três formas, (b) atualizar as normas expandindo a representatividade das amostras e produzindo-se normas para diferentes combinações de idade, escolaridade e sexo, (c) descrever padrões de desenvolvimento da inteligência a partir da escala, comum, produzida entre 6 e 52 anos. Dois estudos foram relatados, o primeiro sobre a calibração dos parâmetros segundo o modelo de Rasch indicando um bom ajuste ao modelo. O segundo estudo exemplificou a utilização de regressão múltipla para criação de normas para testes psicológicos, considerando as variáveis idade, escolaridade e sexo como preditoras dos escores na BPR-5. Essas três variáveis tiveram efeitos significativos explicando 8% (Raciocínio Abstrato), 13% (Raciocínio Verbal), 12% (Raciocínio Espacial), 8% (Raciocínio Numérico) e 22% (Raciocínio Mecânico).(AU)


The Reasoning Tests Battery (BPR-5) is widely used in Brazil for the assessment of intelligence. It has three different forms: children (1st to 6th grade of elementary school), Form A (7th to 9th grade of elementary school) and Form B (high school and higher education). This study describes the steps followed to create a common metric across the forms. It aimed to: (a) calibrate the items of the three forms using Rasch model, link items and equate subjects' scores across forms using the anchoring of common items method, (b) update the norms by expanding the representativeness of the samples by producing norms for different combinations of age, education and sex, and (c) describe the developmental patterns of the BPR-5 subtests across a wide age range, from 6 to 52 years. We present two studies, the first reporting the calibration of item and person parameters with the Rasch model and a good fit to the model. The second illustrated the use of multiple regression analysis to create norms for the psychological tests considering the variables age, education and gender as predictors of the BPR-5 scores. These three variables had significant effects explaining 8% (Abstract Reasoning), 13% (Verbal Reasoning), 12% (Spatial Reasoning), 8% (Numerical Reasoning) and 22% (Mechanical Reasoning) of the variance. (AU)


La Batería de Pruebas de Razonamiento (BPR-5) es un instrumento muy utilizado para la evaluación de la inteligencia en Brasil, disponiendo de tres formas: infantil (1° al 6° año de la Enseñanza Fundamental), Forma A (7° al 9° año de la Enseñanza Fundamental) y Forma B (Bachillerato y Educación Superior). Teniendo como finalidad la posibilidad de comparar los resultados entre sujetos que responden a diferentes versiones, el presente estudio tuvo como objetivo: (a) calibrar los ítems de las tres formas por el modelo de Rasch, realizando la igualación por ítems comunes a fin de obtener una escala equiparable para las tres formas, (b) actualizar las normas ampliando la representatividad de las muestras y produciendo normas para diferentes combinaciones de edad, escolarización y sexo, (c) describir patrones de desarrollo de la inteligencia a partir de la escala, común, producida entre los 6 y los 52 años. Dos estudios fueron reportados, el primer sobre la calibración de los parámetros de acuerdo con el modelo de Rasch, indicando un buen ajuste al modelo. El segundo estudio ejemplificó la utilización de regresión múltiple para crear normas para tests psicológicos, considerando las variables edad, educación y sexo como predictivos de los escores en el BPR-5. Esas tres variables tuvieron efectos significativos explicando 8% (Razonamiento Abstracto), 13% (Razonamiento Verbal), 12% (Razonamiento Espacial), 8% (Razonamiento Numérico), y 22% (Razonamiento Mecánico).(AU)


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Young Adult , Intelligence , Intelligence Tests/standards , Psychometrics , Calibration/standards , Regression Analysis , Educational Status , Age and Sex Distribution
3.
Rio de Janeiro; rBLH; 2 rev; set. 2021. [8] p. ilus.(Normas técnicas BLH-IFF/NT, 1, 44). (BLH-IFF/NT 44.21).
Monography in Spanish, Portuguese | LILACS, BVSAM | ID: biblio-1436547

ABSTRACT

Esta Norma Técnica tem por objetivo estabelecer as orientações necessárias para aferição e leitura dos termômetros utilizados no controle de temperatura nos Bancos de Leite Humano e Postos de Coleta de Leite Humano, visando a garantia da qualidade nestes serviços e sua certificação.


Esta Norma Técnica tiene como objetivo establecer las orientaciones necesarias para la medición y la lectura de los termómetros utilizados en el control de la temperatura en los Bancos de Leche Humana y en los Centros de Recolección de Leche Humana, con el fin de garantizar la calidad de estos servicios y su certificación.


Subject(s)
Quality Control , Temperature , Thermometers/standards , Calibration/standards , Milk Banks/standards , Milk, Human
4.
Rev. cuba. anestesiol. reanim ; 16(2): 12-18, may.-ago. 2017. ilus, tab
Article in Spanish | LILACS, CUMED | ID: biblio-960304

ABSTRACT

Introducción: La calibración de los transductores tiene gran importancia para la medición precisa de las presiones, durante la monitorización hemodinámica invasiva de los pacientes que requieren observación estrecha en las unidades de atención al grave y en el quirófano. Objetivo: Desarrollar y validar un método de calibración para transductores de presión, sencillo, eficaz y de bajo costo. Métodos: Se desarrolló un método manométrico alternativo, basado en la ley de Pascal, para la calibración de los transductores de presión durante la monitorización hemodinámica invasiva que se realiza en la Unidad de Cuidados Intensivos de Cirugía Cardiovascular del Hospital Clínico-Quirúrgico Hermanos Ameijeiras. Este método fue validado mediante la comparación con el estándar recomendado en un total de 215 pacientes que requirieron monitorización hemodinámica invasiva entre los meses de enero y junio del 2015. Resultados: Con el método manométrico alternativo creado se obtiene el mismo resultado que con el método hidráulico recomendado por la literatura. Conclusiones: El método alternativo creado es preciso, eficaz y costo-efectivo(AU)


Introduction: Transducer calibration is very important for the accurate measurement of pressures during invasive hemodynamic monitoring of patients requiring close observation in the primary care units and in the operating room. Objective: To develop and validate a method of calibration of pressure transducers, which is simple, efficient and low-cost. Methods: An alternative manometric method, based on Pascal's law, was developed for the calibration of pressure transducers during invasive hemodynamic monitoring performed at the intensive care unit of the cardiovascular surgery department at Hermanos Ameijeiras Clinical-Surgical Hospital. This method was validated by its comparison with the recommended standard in a total of 215 patients who required invasive hemodynamic monitoring between January and June 2015. Results: With the alternative manometric method created, the same result was obtained as with the hydraulic method recommended by the literature. Conclusions: The alternative method created is accurate, efficient and cost-effective(AU)


Subject(s)
Humans , Transducers, Pressure/standards , Calibration/standards , Inventions/standards , Hemodynamic Monitoring/instrumentation
6.
Braz. j. med. biol. res ; 48(10): 908-914, Oct. 2015. tab, ilus
Article in English | LILACS | ID: lil-761605

ABSTRACT

Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.


Subject(s)
Adult , Humans , Male , Chromosome Aberrations/radiation effects , Dose-Response Relationship, Radiation , Electrons , Leukocytes, Mononuclear/radiation effects , Particle Accelerators , Calibration/standards , Primary Cell Culture , Radiation Dosage , Radiometry/methods
7.
Article in English | AIM | ID: biblio-1268130

ABSTRACT

How to ensure that your mobile audiometer is always calibrated according to SABS standards


Subject(s)
Acoustics , Calibration/standards , Cell Phone , Hearing Tests
8.
Rev. bras. cir. cardiovasc ; 29(1): 1-8, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-710090

ABSTRACT

Introdução: O modelo mais utilizado para predição de mortalidade em cirurgia cardíaca foi recentemente remodelado, mas dúvidas referentes à sua metodologia e desenvolvimento têm sido relatadas. Objetivo: O objetivo deste estudo foi avaliar o desempenho do EuroSCORE II na predição de mortalidade em pacientes submetidos a cirurgia de coronária e/ou valva na instituição. Métodos: Mil pacientes, operados consecutivamente de coronária e/ou valva, entre outubro de 2008 e julho de 2009, foram analisados. O desfecho de interesse foi mortalidade intra-hospitalar. A calibração foi realizada pela correlação entre mortalidade esperada e observada por meio do teste de Hosmer Lemeshow. A discriminação foi calculada pela área abaixo da curva ROC. O desempenho do EuroSCORE II foi comparado com os modelos EuroSCORE e InsCor (modelo local). Resultados: Na calibração, o teste de Hosmer Lemeshow foi inadequado para o EuroSCORE II (P=0,0003) e bom para os modelos EuroSCORE (P=0,593) e InsCor (P=0,184). No entanto, na discriminação, a área abaixo da curva ROC para o EuroSCORE II foi de 0,81 [IC 95% (0,76-0,85), P<0,001]; para o EuroSCORE foi de 0,81 [IC 95% (0,77-0,86), P<0,001] e para o InsCor foi de 0,79 [IC 95% (0,74-0,83), P<0,001], revelando-se adequada para todos. Conclusão: O EuroSCORE II se tornou mais complexo e, à semelhança com a literatura internacional, mal calibrado para predizer mortalidade nos pacientes operados de coronária e/ou valva em nosso meio. Esses dados reforçam a importância do modelo local. .


Introduction: The most widely used model for predicting mortality in cardiac surgery was recently remodeled, but the doubts regarding its methodology and development have been reported. Objective: The aim of this study was to assess the performance of the EuroSCORE II to predict mortality in patients undergoing coronary artery bypass grafts or valve surgery at our institution. Methods: One thousand consecutive patients operated on coronary artery bypass grafts or valve surgery, between October 2008 and July 2009, were analyzed. The outcome of interest was in-hospital mortality. Calibration was performed by correlation between observed and expected mortality by Hosmer Lemeshow. Discrimination was calculated by the area under the ROC curve. The performance of the EuroSCORE II was compared with the EuroSCORE and InsCor (local model). Results: In calibration, the Hosmer Lemeshow test was inappropriate for the EuroSCORE II (P=0.0003) and good for the EuroSCORE (P=0.593) and InsCor (P=0.184). However, the discrimination, the area under the ROC curve for EuroSCORE II was 0.81 [95% CI (0.76 to 0.85), P<0.001], for the EuroSCORE was 0.81 [95% CI (0.77 to 0.86), P<0.001] and for InsCor was 0.79 [95% CI (0.74-0.83), P<0.001] showing up properly for all. Conclusion: The EuroSCORE II became more complex and resemblance to the international literature poorly calibrated to predict mortality in patients undergoing coronary artery bypass grafts or valve surgery at our institution. These data emphasize the importance of the local model. .


Subject(s)
Female , Humans , Male , Coronary Artery Bypass/mortality , Heart Valve Prosthesis Implantation/mortality , Models, Theoretical , Risk Assessment/methods , Calibration/standards , Coronary Disease/mortality , Coronary Disease/surgery , Hospital Mortality , Heart Valve Diseases/mortality , Heart Valve Diseases/surgery , Reference Values , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity
9.
Arq. bras. cardiol ; 100(3): 246-254, mar. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-670865

ABSTRACT

FUNDAMENTO: Escores de risco apresentam dificuldades para obter o mesmo desempenho em diferentes populações. OBJETIVO: Criar um modelo simples e acurado para avaliação do risco nos pacientes operados de doença coronariana e/ou valvar no Instituto do Coração da Universidade de São Paulo (InCor-HCFMUSP). MÉTODOS: Entre 2007 e 2009, 3.000 pacientes foram operados consecutivamente de doença coronariana e/ou valvar no InCor-HCFMUSP. Desse registro, dados de 2/3 dos pacientes foram utilizados para desenvolvimento do modelo (técnica de bootstrap) e de 1/3 para validação interna do modelo. O desempenho do modelo (InsCor) foi comparado aos complexos 2000 Bernstein-Parsonnet (2000BP) e EuroSCORE (ES). RESULTADOS: Apenas 10 variáveis foram selecionadas: Idade > 70 anos; sexo feminino; cirurgia de revascularização coronariana + valva; infarto de miocárdio < 90 dias; reoperação; tratamento cirúrgico da valva aórtica; tratamento cirúrgico da valva tricúspide; creatinina < 2mg/dL; fração de ejeção < 30%; e eventos. O teste de Hosmer Lemeshow para o InsCor foi de 0,184, indicando uma excelente calibração. A área abaixo da curva ROC foi de 0,79 para o InsCor, 0,81 para o ES e 0,82 para o 2000BP, confirmando que os modelos são bons e similares na discriminação. CONCLUSÕES: O InsCor e o ES tiveram melhor desempenho que o 2000BP em todas as fases da validação; pórem o novo modelo, além de se identificar com os fatores de risco locais, é mais simples e objetivo para a predição de mortalidade nos pacientes operados de doença coronariana e/ou valvar no InCor-HCFMUSP.


BACKGROUND: Risk scores show difficulties to attain the same performance in different populations. OBJECTIVE: To create a simple and accurate risk assessment model for patients submitted to surgery due to coronary and/or valvular disease at Instituto do Coração da Universidade de São Paulo (InCor-HCFMUSP). METHODS: Between 2007 and 2009, 3,000 patients were submitted to surgical procedure due to coronary artery and/or valvular disease at InCor-HCFMUSP. From this record, data of 2/3 of the patients were used for model development (bootstrap technique), and 1/3 for internal validation of the model. The performance of the model (InsCor) was compared to the 2000 Bernstein-Parsonnet (2000BP) and EuroSCORE (ES) complexes. RESULTS: Only 10 variables were selected: age > 70 years, female sex; coronary revascularization + valve, myocardial infarction < 90 days; reoperation; surgical treatment of aortic valve; surgical treatment of tricuspid valve; creatinine < 2mg/dL; ejection fraction < 30%, and events. The Hosmer Lemeshow test for the InsCor was 0.184, indicating excellent calibration. The area under the ROC curve was 0.79 for the InsCor, 0.81 for the ES and 0.82 for 2000BP, confirming that the models are good and have similar discrimination. CONCLUSIONS: The InsCor and ES performed better than 2000BP at all stages of validation, but the new model, in addition to showing identification with the local risk factors, is simpler and more objective for mortality prediction in patients undergoing surgery due to coronary and/or valvular disease at InCor-HCFMUSP.


Subject(s)
Aged , Female , Humans , Cardiac Surgical Procedures/mortality , Coronary Artery Disease/surgery , Heart Valve Diseases/surgery , Calibration/standards , Models, Statistical , Reproducibility of Results , ROC Curve , Risk Assessment/methods , Risk Assessment/standards
10.
Rev. salud pública ; 12(1): 126-134, feb. 2010. ilus
Article in Spanish | LILACS | ID: lil-552325

ABSTRACT

Objetivo Analizar los aspectos metrológicos fundamentales que se deben tener en cuenta en la elaboración de los procedimientos de calibración de equipo electromédico, que permitan acreditar en Colombia, laboratorios de metrología electromédica con base en la normatividad internacional. Métodos Con base en las normas NTC-ISO-IEC 17025:2005 y GTC-51, se diseñaron e implementaron procedimientos para la calibración de equipo electromédico, contando para ello con un conjunto completo de analizadores de equipos electromédicos que fueron utilizados como patrones. Resultados El modelo matemático para determinar el valor estimado de incertidumbre en la calibración de equipos electromédicos, para la acreditación del área de Calibración de Equipos Electromédicos del Laboratorio de Metrología de Variables Eléctricas, acreditado según Resolución 25771 del 26 mayo de 2009 de la Superintendencia de Industria y Comercio, consta de dos ecuaciones según sea el caso; ellas son: y Conclusión El modelamiento matemático implementado para el cálculo de incertidumbre de medición en el proceso de acreditación del área de calibración de equipos electromédicos del Laboratorio de Metrología de Variables Eléctricas, de la Universidad Tecnológica de Pereira, constituye una buena guía para futuros procesos de calibración que emprendan otros laboratorios de Colombia y Latinoamérica.


Objective Analysing the fundamental methodological aspects which should be considered when drawing up calibration procedure for electro-medical equipment, thereby permitting international standard-based accreditation of electro-medical metrology laboratories in Colombia. Methods NTC-ISO-IEC 17025:2005 and GTC-51-based procedures for calibrating electro-medical equipment were implemented and then used as patterns. Results The mathematical model for determining the estimated uncertainty value when calibrating electro-medical equipment for accreditation by the Electrical Variable Metrology Laboratory's Electro-medical Equipment Calibration Area accredited in compliance with Superintendence of Industry and Commerce Resolution 25771 May 26th 2009 consists of two equations depending on the case; they are: and Conclusion The mathematical modelling implemented for measuring uncertainty in the Universidad Tecnológica de Pereira's Electrical Variable Metrology Laboratory (Electro-medical Equipment Calibration Area) will become a good guide for calibration initiated in other laboratories in Colombia and Latin-America.


Subject(s)
Accreditation , Calibration/standards , Electrical Equipment and Supplies/standards , Laboratories/standards , Colombia , Mathematics , Reproducibility of Results
11.
Rev. bras. eng. biomed ; 25(3): 145-152, dez. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-576299

ABSTRACT

Neste trabalho descrevemos um sistema on-line, chamado “Dose Fetal Web”, que calcula a dose fetal e os riscos radiológicos devido a exposições clínicas ou ocupacionais de gestantes. O sistema utiliza a metodologia matemática onde são usados coeficientes de conversão de dose uterina para dose fetal, gerados por meio de simulações pelo método de Monte Carlo. Para exposição médica de uma paciente gestante, uma base de dados de informações de operação de equipamentos acompanhados por um programa de garantia de qualidade e parâmetros fetais e maternos coletados durante exames de ultrassonografia obstétrica são incorporados na estimativa da dose fetal. No caso de dose fetal de uma trabalhadora gestante sujeita à exposição ocupacional (IOE),informações de uma base de dados de monitoração pessoal como dose ocupacional e carga de trabalho são usadas nos cálculos. No primeiro caso, considerando-se uma paciente gestante de 26 semanas submetida a um procedimento abdominal AP (tensão aplicada ao tubo de 70 kVp e filtração total de 3 mmAl), a dose fetal calculada pelo sistema foi 4,61 mGy e os riscos radiológicos obtidos foram 5,0·10-4 e 0,14 para a probabilidade de indução de retardamento mental e declínio de pontos de QI, respectivamente. No segundo caso, considerando-se uma IOE gestante, e assumindo-se que ela utilize um avental de proteção de 0,5 mm de equivalência em chumbo durante cada procedimento de radiologia intervencionista, e que a leitura pessoal de um dosímetro TLD portado fora do avental foi de 2 mGy/mês, a dose fetal calculada pelo sistema foi 0,02 mSv/mês.


In this paper we describe an online software, named “Dose Fetal Web”, which calculates the dose of the fetus and the radiological risks from both medical and occupational exposures of pregnant women. The software uses a mathematical methodology where coefficients for converting uterus to fetal dose, NUD, have been calculated by using Monte Carlo simulation. In the fetal dose from diagnostic medical examination of the pregnant patient, database information regarding output and other equipment related parameters from the QA database, maternal and fetal parameters collected by ultrasound procedures were used for the fetal dose estimation. In the case of fetal dose of the pregnant staff member the database information regarding routine individual monitoring dosimetry, such as occupational dose and workload, were used for the estimation. In the first case, suppose a 26 weeks pregnant patient had to undergo a single AP Abdomen procedure (70 kVp peak tube voltage and total filtration 3 mmAl), the fetal dose calculated by the software was 4.61 mGy and the radiological risks would be 5.0·10-4 and 0.14 to the probability of mental retardation induction and decline in the IQ score, respectively. In the second case,considering that the staff member can be pregnant, and assuming that she wore a 0.5 mm lead equivalent apron during every interventional radiology procedure and a personal dosimetry reading of 2 mGyTLD/month measured with the TLDs outside the apron, the fetal dose calculated by the software was 0.02 mSv/month.


Subject(s)
Humans , Female , Pregnancy , Radiotherapy Dosage/standards , Fetus/radiation effects , Pregnancy/radiation effects , Radiation Protection/instrumentation , Radiotherapy, Computer-Assisted/instrumentation , Radiotherapy, Computer-Assisted/standards , Radiotherapy, Computer-Assisted , Maternal-Fetal Exchange/radiation effects , Calibration/standards , Maternal Exposure/adverse effects , Maternal Exposure/prevention & control , Internet/trends , Internet , Occupational Risks , Radiation Exposure Measurement
12.
Arq. bras. oftalmol ; 72(3): 346-350, May-June 2009. ilus, graf, tab
Article in English | LILACS | ID: lil-521469

ABSTRACT

PURPOSE: To determine calibration errors of Goldmann applanation tonometers in ophthalmic clinics of Brasília, Brazil, and correlate the findings with variables related to tonometers model and utilization. METHODS: Tonometers from ophthalmic clinics in Brasília, Brazil, were checked for calibration errors. A standard Goldmann applanation tonometer checking tool was used to asses the calibration error. Only one trained individual made all verifications, with a masked reading of the results. Data on the model, age, daily use, frequency of calibration checking and the nature of the ophthalmic department - private or public - were collected and correlated with the observed errors. RESULTS: One hundred tonometers were checked for calibration. Forty seven percent (47/100) were out of 1 mmHg range at least at one point checking. Tonometers mounted to slit lamp, with less than 5 years, used in less than 20 patients daily, that had a calibration check on a yearly basis, and those from private office exhibit a lower rate of inaccuracy, but only the first variable was statistically significant. Sixty one percent of tonometers on public hospitals were out of calibration. CONCLUSION: Calibration of tonometers in the capital of Brazil is poor; those from general hospitals are worst, and this fact can lead to inaccurate detection and assessment of glaucoma patients, overall in the population under government assistance.


OBJETIVOS: Determinar os erros de calibração dos tonômetros de aplanação de Goldmann em clínicas oftalmológicas de Brasília, Brasil, e correlacioná-los a variáveis relativas ao modelo e à utilização dos aparelhos. MÉTODOS: Tonômetros de clínicas oftalmológicas de Brasília tiveram a calibragem aferida usando um cilindro padrão fornecido pelo fabricante dos aparelhos. Todas as aferições foram realizadas por um só examinador previamente treinado e a leitura das medidas foi mascarada por um observador independente. As medidas foram correlacionadas ao modelo, idade, utilização diária e frequência de aferição da calibração dos tonômetros, bem como o serviço em que o aparelho era utilizado - público ou privado. RESULTADOS: Cem tonômetros foram avaliados. Quarenta e sete por cento (47/100) apresentaram erros de leitura maiores ou iguais a 1 mmHg em pelo menos um ponto de aferição, sendo considerados descalibrados. Tonômetros fixos à lâmpada de fenda, com menos de 5 anos de fabricação, usados em menos de 20 pacientes por dia, que tinham a calibragem aferida ao menos anualmente e que eram utilizados em clínicas privadas apresentaram menos descalibragem, porém apenas a primeira variável foi estatisticamente significante. Sessenta e um por cento dos tonômetros de hospitais públicos estavam descalibrados. CONCLUSÕES: A calibragem de tonômetros avaliados em Brasília é precária. A situação é pior nos aparelhos dos hospitais públicos, podendo levar a erros na detecção e no acompanhamento de pacientes com glaucoma atendidos nesses serviços.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Brazil , Cross-Sectional Studies , Calibration/standards , Equipment Failure Analysis/methods , Hospitals, Private/statistics & numerical data , Hospitals, Public/statistics & numerical data , Ophthalmology , Quality Control , Tonometry, Ocular/standards
13.
J. pediatr. (Rio J.) ; 85(1): 84-86, jan.-fev. 2009. tab
Article in English, Portuguese | LILACS | ID: lil-507704

ABSTRACT

OBJETIVO: O monitoramento do pH esofágico é considerado o método mais confiável para diagnosticar o refluxo gastroesofágico. No entanto, a interpretação do mesmo estudo de pH pode diferir entre observadores. Neste estudo, investigamos as causas e o grau de variabilidade entre observadores. MÉTODOS: Este estudo retrospectivo incluiu todas as crianças (n = 72) que realizaram monitoramento de pH durante 1 ano no Maxima Medical Centre, em Veldhoven, Holanda. RESULTADOS: Foi encontrada uma variabilidade de 18 por cento entre observadores. A variabilidade foi causada por diferenças de opinião sobre a duração do registro, dúvidas sobre a posição da sonda, artefatos e flutuação do pH de base. CONCLUSÕES: A maioria desses problemas pode ser eliminada por avaliação da posição do eletrodo de pH e calibração pós-teste. No entanto, ainda falta uma definição clara dos artefatos de monitoramento. Este estudo mostra que a concordância mútua na interpretação dos estudos de pH foi regular (coeficiente kappa de 0,70).


OBJECTIVE: To investigate the causes and degree of interobserver variability in esophageal pH monitoring for the diagnosis of gastroesophageal reflux. METHODS: This retrospective study included all children (n = 72) who underwent pH monitoring during 1 year at Maxima Medical Centre in Veldhoven, the Netherlands. RESULTS: An interobserver variability of 18 percent was found. Variability was caused by differences in opinion about the duration of registration, doubts about probe position, artifacts and drift of baseline pH. CONCLUSIONS: Most of these problems can be eliminated by posttest calibration and assessment of the pH electrode position. However, a clear definition of monitoring artifacts is lacking. This study shows that mutual agreement in the interpretation of pH studies was fair (kappa coefficient of 0.70).


Subject(s)
Female , Humans , Infant , Male , Esophageal pH Monitoring/statistics & numerical data , Gastroesophageal Reflux/diagnosis , Calibration/standards , Electrodes, Implanted/standards , Observer Variation , Retrospective Studies
14.
Rev. bras. eng. biomed ; 24(3): 201-214, dez. 2008.
Article in Portuguese | LILACS | ID: lil-548021

ABSTRACT

Neste artigo é apresentado um procedimento para avaliação e qualificação de medidores potenciométricos de pH, fundamentadoem normas técnicas nacionais, internacionais e normas da qualidade. O objetivo é introduzir um procedimentoque propicie o uso adequado do medidor de pH e leve à padronização da avaliação do equipamento e melhoriana confiabilidade dos resultados obtidos. O procedimento consiste em avaliar o medidor de pH por meio de um formulário cujos quesitos baseiam-se na inspeção do medidor, acessórios, insumos, documentação e testes. Para avaliar a aplicabilidade do método proposto, foram testados medidores de pH pertencentes a laboratórios de Curitiba. Nesses testes constatou-se que o procedimento permite definir critériosadequados de análise, pois abrange todas as fases do processo, o que permite evidenciar não-conformidades em todas elas, desde a seleção do medidor de pH, procedimento de controle e acompanhamento do processo até a emissão do parecer final. Os resultados in situ indicaram que a maioria dos medidores de pH apresentavam não-conformidadescom as normas vigentes. Observou-se a necessidade de manutenção periódica dos medidores e treinamento dos técnicos que realizam os ensaios. Constatou-se também que os profissionais não dedicam a devida atenção ao ensaio de medição de pH por considerá-lo simples, o que certamente contribui para a ocorrência de resultados incorretos.


In this article we describe a procedure for evaluating and qualifyingpotentiometric pH meters based on Brazilian and international technical standards and Brazilian quality standards. The aim of the study was to introduce a procedure that will enable pH meters to be used correctly and lead to a standardized approach to the evaluation of this instrument, as well as allowing more reliable results to be obtained. The procedure involves evaluating the pH meter by using an assessment form that covers inspection of the meter, accessories, supplies, documentation and tests. The feasibility of the proposed method was evaluated by testing pH meters belonging to a number of laboratories in Curitiba (Brazil). As a result of these tests it was found that the procedure allows suitable analytical criteria to be defined, as it covers all phases of the process, from the initial selection of the pH meter, through the procedure for controlling and following up the process, to the release of the final report, and therefore allows any non-compliance to be identified. The in situ results show that most of the meters tested do not comply with the prevailing standards and that regular routine maintenance needs to be carried out as well as training given to the technicians who perform the tests. It was also observed that the staff who use the pH meters do not take enough care when carrying out pH measurements because they believe it is a simple procedure, a fact which undoubtedly contributes to incorrect results.


Subject(s)
Hydrogen-Ion Concentration , Speed Meters , Calibration/standards , Quality Control , Documentation/methods , Reference Standards
15.
Rev. med. nucl. Alasbimn j ; 11(42)oct. 2008. ilus, graf
Article in Spanish | LILACS | ID: lil-504083

ABSTRACT

Un programa de control de calidad en medicina nuclear incluye la verificación de la eficiencia de equipos utilizados para el diagnóstico y tratamiento, hasta la formación. En este estudio se evaluaron las medidas de actividad realizada por los usuarios que trabajan en los servicios de medicina nuclear en Sergipe, Brazil. En las medidas de actividad se estableció uno y se caracteriza entre las medidas de fuentes radiactivas selladas de actividad normal, 133Ba y 57Co, llevada a cabo por distintos profesionales, con el fin de comprobar la reproducibilidad de estas medidas cuando se compara con el valor por defecto de la actividad de cada fuente. Los resultados de inter-medidas en estado satisfactorio y pueden ser utilizados como parámetros en el evaluación futuro de los servicios de medicina nuclear.


A program of quality control program in nuclear medicine includes the verification of the efficiency of any equipment used for diagnosis and treatment, until the personal training. In this study were evaluated measures of activity undertaken by users who work in nuclear medicine services in Sergipe, Brazil. In measures of activity was established and characterized an inter measures of activity sealed radioactive sources standard, 133Ba and 57Co, carried out by different professionals, aiming to verify the reproducibility of these measures when compared with the default value of the activity of each source. The results of inter-measures were in satisfactory and can be used as parameters in future evaluation services in nuclear medicine.


Subject(s)
Humans , Quality Assurance, Health Care , Nuclear Medicine/standards , Radiometry/standards , Brazil , Calibration/standards , Quality Control , Reference Standards , Reproducibility of Results
16.
Rev. salud pública ; 10(3): 462-469, jul. 2008. tab
Article in Spanish | LILACS | ID: lil-497310

ABSTRACT

Objetivo Determinar las características de calidad relacionadas con el seguimiento de patrones de calibración del equipo biomédico y su seguridad eléctrica, imple-mentadas por las entidades prestadoras del servicio de salud en el Departamento de Risaralda. Métodos Estudio descriptivo. Utilizando muestreo no probabilístico con criterio de mayor inventario de equipos y demanda de servicios, para las categorías de Clínicas, Centros de Estética, Radiología y Odontología, y para la de Hospitales, censo; el instrumento se aplicó a 32 entidades prestadoras del servicio de salud, distribuidas en los 14 municipios del Departamento de Risaralda, entre Septiembre 2005-Enero 2006. Resultados Las categoría con mayor equipo electromédico es la de Hospitales con el 56 por ciento. Pereira, la capital de Risaralda, tiene el 81 por ciento de los equipos electromédicos. Todas las entidades están sin acreditación en norma NTC-ISO-IEC-17025 certificada por Superintendencia de Industria y Comercio -SIC. Ninguna entidad de las contratadas externamente por las entidades encuestadas, se encuentra acreditada. Conclusiones En el Departamento de Risaralda existe riesgo de salud pública. Las entidades prestadoras del servicio de salud, están sin acreditación en norma NTC-ISO-IEC-17025 y las entidades externas que a su vez son contratadas por estas, para calibración de sus equipos, tampoco se encuentran acreditadas. Con base en la información obtenida en equipos sin calibrar con patrones internacionales, los diagnósticos tienen gran potencial para ser errados. También coloca en desventaja competitiva a las entidades de salud, frente a otras que se encuentren acreditadas y que estén ubicadas en Colombia o en otros países.


Objective Determining quality features related to tracking biomedical equipment calibration patterns and their electrical safety as implemented by Health Care Institutions in the Risaralda department. Methods This was a descriptive study using non-probabilistic sampling and the criterion of a greater equipment inventory and service demand for Clinics, Aesthetic, Radiology and Dentistry Centres and Hospitals. Census; the instrument was applied to 32 health-care institutions distributed throughout the Risaralda department’s 14 municipalities between September 2005 and January 2006. Results Hospitals was the category having a highest number of electro-medical equipment (56 percent). Pereira (the capital of Risaralda) had 81 percent of all electro-medical equipment. All the institutions lacked NTC-ISO-IEC-17025 accreditation regarding standards certified by the Superintendence of Industry and Commerce. None of the institutions externally contracted by the institutions being surveyed was accredited. Conclusions There is a public health risk in the Risaralda department; all health-care institutions lacked NTC-ISO-IEC-17025 accreditation and external institutions (in turn being hired by them for calibrating their equipment) also lacked accreditation. Based on the information obtained from non-calibrated equipment having international patterns, there is a great danger that determining the quality of biomedical equipment calibration patterns may be erroneous. It also places health-care institutions at a competitive disadvantage when compared to other accredited institutions in Colombia or in other countries.


Subject(s)
Calibration/standards , Equipment and Supplies/standards , Colombia , Health Facilities
17.
Rev. bras. eng. biomed ; 24(1): 39-49, abr. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-510113

ABSTRACT

No método de calibração por auto-reciprocidade, a sensibilidade do transdutor é determinada a partir do conhecimento de parâmetros elétricos de excitação do transdutor (tensão e corrente), além de outras grandezas presentes no parâmetro geral de reciprocidade para ondas planas JP. O objetivo deste trabalho é validar um sistema de calibração por auto-reciprocidade, conforme a norma IEC 60866:1987. A validação foi realizada utilizando-se um padrão de referência calibrado no National Physical Laboratory (NPL) em conjunto com transdutores com freqüência central de 1,0 MHz e 2,25 MHz. Para a validação do sistema de calibração, a tensão de alimentação aplicada aos transdutores foi variada de 1 a 10 V, medidos pico a pico, na faixa de 0,80 a 1,32 MHz para o transdutor de 1,0 MHz e na faixa de 1,5 a 3,0 MHz para o transdutor de 2,25 MHz. Foram considerados válidos os pontos em freqüência cujos resultados da calibração tiveram incerteza devido à linearidade máxima menor do que 10% e incerteza combinada menor do que 9%. O sistema foi validado na faixa de 1,04 a 1,32 MHz (com base nos resultados do transdutor de 1,0 MHz) e na faixa 1,55 a 2,90 MHz (utilizando-se o transdutor de 2,25 MHz). Nas freqüências próximas à freqüência de ressonância, a incerteza combinada típica do transdutor de 1,0 MHz foi de cerca de 5%, e a do transdutor de 2,25 MHz em torno de 8%. A faixa reduzida do primeiro transdutor deu-se por restrições do sistema experimental utilizado, particularmente pelos dados de calibração do padrão de referência utilizado. O sistema se mostrou adequado e os resultados foram considerados dentro do padrão esperado.


According to the self-reciprocity calibration method, ultrasonic transducer sensitivity is depicted from the knowledge of electrical parameters of excitation (voltage and electric current), as well as other quantities expressed in the general reciprocity parameters for plane waves...


Subject(s)
Transducers/standards , Ultrasonics , Ultrasonography , Calibration/standards , Equipment Maintenance/methods , Quality Control , Reference Standards
18.
Rev. HCPA & Fac. Med. Univ. Fed. Rio Gd. do Sul ; 28(3): 142-146, 2008. tab, ilus
Article in Portuguese | LILACS | ID: lil-566974

ABSTRACT

Introdução: A avaliação da função renal deve ser realizada através da estimativa da taxa de filtração glomerular (TFG) com a equação do estudo Modification of Diet in Renal Disease (MDRD), a qual inclui a idade, gênero, etnia e creatinina. No entanto, a medida da creatinina requer rastreabilidade com método padrão (equiparação) para sua calibração. Objetivo: Verificar o impacto da calibração da creatinina na TFG calculada pela fórmula do MDRD. Métodos: Foram analisadas 140 amostras de soro com creatinina <2,0 mg/dl pela reação de Jaffé com Creatinina Modular P (Roche ®; método A; calibrado) e pela Creatinina Advia 1650 (Bayer ®; método B; não calibrado). Os resultados obtidos foram comparados entre si e alinhados por fórmula de conversão. A TFG foi estimada através da fórmula do MDRD. Resultados: O método B teve resultados mais altos que o método A (1,03 ± 0,29 vs. 0,86 ± 0,32 mg/dl, P<0,001). Esta diferença diminuiu quando os resultados do método B foram alinhados ao método A através da equação y=1,07x -0,249, sendo os valores do método alinhado por regressão de 0,9 ± 0,31 mg/dl. O método não calibrado identificou 10% mais de casos de doença renal renal crônica (falso positivos). Essa discordância desaparece após o alinhamento. Conclusão: A calibração dos métodos de creatinina tem um impacto importante nos resultados finais de creatinina e TFG. O alinhamento de resultados não padronizados através de fórmulas de conversão pode ser uma alternativa para harmonizar os resultados de creatinina sérica enquanto programas internacionais de padronização não estiverem ainda totalmente implantados.


Background: The evaluation of renal function should be performed with glomerular filtration rate (GFR) estimation employing the Modification of Diet in Renal Disease (MDRD) study equation, which includes age, gender, ethnicity and serum creatinine. However, creatinine methods require traceability with standardized methods. Objective: To analyse the impact of creatinine calibration on MDRD calculated GFR. Methods: 140 samples of plasma with creatinine values <2.0 mg/dl were analysed by Jaffé’s reaction with Creatinina Modular P (Roche ®; method A; reference) and Creatinina Advia 1650 (Bayer ®; method B; nonstandardized). The results with the different methods were compared and aligned with standardized method through a conversion formula. MDRD GFR was estimated. Results: Values were higher for method B (1.03 ± 0.29 vs. 0.86 ± 0.32 mg/dl, P<0.001). This difference declined when methods were aligned with the equation y=1.07x - 0.249, and the aligned values were 0.9 ± 0.31 mg/dl. Non-traceable creatinine methods misclassificaed chronic kidney disease in 10% more (false positive). This disagreement disappeared after the regression alignment. Conclusion: Creatinine method calibration has a large impact over the final results of serum creatinine and GFR. The alignment of the non-standardized results through conversion formulas is a reasonable alternative to harmonize serum creatinine results while waiting for the full implementation of international standardization programs.


Subject(s)
Humans , Male , Female , Creatinine/analysis , Glomerular Filtration Rate , Calibration/standards , Biomarkers
19.
Pakistan Journal of Pharmaceutical Sciences. 2007; 20 (2): 163-174
in English | IMEMR | ID: emr-84728

ABSTRACT

Calibration allows the user to relate instrumental measurements to the sample of interest. Multivariate calibration allows for the analysis of several measurements from several samples or specimens. The method contributes to the two steps procedure where step one involves the calibration of data and second step involves the prediction that are made or based on the calibration. In calibration, indirect measurements are made from samples where the amount of the analyte has been predetermined, usually by an independent assay or technique. These measurements, along with the predetermined analyte levels, comprise a group known as the calibration set. This set is used to develop a model that relates the amount of sample to the measurements by the instrument. In some cases, the construction of the model is simple due to a certain relationship, such as Beer's Law in the application of UV spectroscopy. Unlike spectroscopy, other cases can be much more complex, and it is in these cases where construction of the model is time-consuming step. Once the model is constructed, it can predict analyte levels based on measurements of new samples. It can be used to separate samples from interferences without the need of highly selective measurements for the analyte. Calibration techniques [used in the calibration step] differ in determining coefficient values for the preceding or similar equations


Subject(s)
Calibration/standards
20.
Radiol. bras ; 39(3): 203-207, maio-jun. 2006. tab, ilus
Article in Portuguese | LILACS | ID: lil-455883

ABSTRACT

OBJETIVO: O objetivo deste trabalho foi realizar uma comparação entre os fatores de calibração em termos de dose absorvida no ar determinados em feixes gama (60Co) e de elétrons. MATERIAIS E MÉTODOS: Foram utilizados um irradiador de 60Co e um acelerador linear Varian, modelo Clinac 2100C, com feixes de fótons e de elétrons. Foram testadas uma câmara de ionização cilíndrica e três de placas paralelas. RESULTADOS: Os sistemas de medidas foram submetidos aos testes preliminares (estabilidade de resposta e corrente de fuga), com resultados muito bons. Os fatores de calibração em termos de dose absorvida no ar foram determinados utilizando-se quatro sistemas de medidas e dois tipos de objetos simuladores, com a obtenção de resultados dentro das recomendações internacionais. CONCLUSÃO: Os resultados mostraram que os fatores de calibração em termos de dose absorvida no ar obtidos para câmaras de ionização de placas paralelas, determinados em feixes de 60Co, são no máximo 1,2 por cento mais altos que os valores obtidos em feixes de elétrons de altas energias.


OBJECTIVE: The objective of this study was to compare the absorbed dose to air calibration factors determined in gamma (60Co) and electron beams. MATERIALS AND METHODS: An irradiator with a 60Co source and a Varian, Clinac 2100C linear accelerator with photon and electron beams were utilized. One thimble-type and three parallel-plate ionization chambers were tested. RESULTS: The measurement systems were submitted to preliminary tests (response stability and leakage current), with quite good results. The absorbed dose to air calibration factors were determined using four measurement systems and two types of phantoms. Results were obtained in compliance with the international recommendations. CONCLUSION: Absorbed dose to air calibration factors obtained for parallel plate ionization chambers, determined in 60Co beams, at maximum, are 1.2 percent higher than the values obtained in high energy electron beams.


Subject(s)
Ions , Radiometry/instrumentation , Technology, Radiologic , Calibration/standards